Logged in as:

Show all filters

Hide all filters

  • Total: 16

EN-Cable, multi conductor


Huber+Suhner
Number of cores:
2-3 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-125 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
24.9-26.7 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX 3 GKW/S EMC


Huber+Suhner
Number of cores:
3-8 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
120 °C
Screen:
Yes, No
Protective barrier:
N/A
Armouring/reinforcement:
Braiding, None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
48.6-240.24 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

CAN, CAN-FD, FlexRay


Huber+Suhner
Number of cores:
2 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Black, Other
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
120 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
52 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX GKW-LW - Multi conductor


Huber+Suhner
Number of cores:
2-12 .
Colour outer sheath:
Black
Nominal voltage:
1500 V
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Conductor surface:
Tinned
Halogen free:
Yes
Low smoke (according to EN 61034-2):
Yes

RXL 125 S2


Huber+Suhner
Number of cores:
4-16 .
Protective conductor:
No
Material outer sheath:
None
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Screen:
No
Drain wire:
No
Nominal voltage:
1000 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Conductor surface:
Tinned
Halogen free:
Yes
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes

RADOX 3 GKW, multi conductor


Huber+Suhner
Number of cores:
2-8 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin, None
Specification material outer sheath:
Other
Colour outer sheath:
Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
120 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
44.7-106.08 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX TENUIS -TW 600V MM


Huber+Suhner
Number of cores:
2-12 .
Colour outer sheath:
Black
Nominal voltage:
1000 V
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Conductor surface:
Tinned
Halogen free:
Yes

RADOX 125 Multi conductor unscreened


Huber+Suhner
Number of cores:
2-27 .
Protective conductor:
No
Material outer sheath:
None
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
1000 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Conductor surface:
Tinned
Halogen free:
Yes
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

SIFF, Silikonkabel


-
Number of cores:
2 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - silicone rubber (SIR)
Core identification:
None
Protective conductor:
No
Material outer sheath:
Rubber
Specification material outer sheath:
Other
Colour outer sheath:
Grey
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-60-180 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
180 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Silicone
Operating temperature:
-50-180 °C
Core colour:
Grey
Conductor surface:
Bare, Tinned
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
25.6 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

SIHF, Silikonkabel


-
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - silicone rubber (SIR)
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Rubber
Specification material outer sheath:
Other
Colour outer sheath:
Red
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-60-180 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
180 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
Yes, No
Conductor category:
Class 5 = flexible
Colour:
Brown/Red
Material insulation:
Silicone
Operating temperature:
-50-180 °C
Core colour:
Red, Several
Conductor surface:
Bare, Tinned
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
25.6-88 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No
Availability:
No

Availability:
No

Availability:
No

Availability:
No

Availability:
No

Availability:
No

  • Total: 16